Check this post for catl 3.2v 280ah pdf. And how it compare with EVE 280ah cell? I’ll write in another post.
The 280Ah 3.2V lithium iron cells are for energy storage system.
1.CATL 280Ah cell LFP specification
No. | Parameter | Specification | Condition |
2.1.1 | Typical capacity | 280 Ah | Refer to 2.2&2.3 standard charge and discharge procedure |
2.1.2 | Typical Energy | 896 Wh | Refer to 2.2&2.3 standard charge and discharge procedure |
2.1.3 | Operating voltage | 2.5~3.65V2.0~3.65V | Cell temperature T>0°C Cell temperature T≤0°C |
2.1.4 | Impedance (1KHz) | 0.17±0.05m Ω | Fresh cell (40%SOC) |
2.1.5 | Shipping capacity | 112±1 Ah | 40% SOC |
No. | Parameter | Specification | Condition |
2.1.6 | Residual capacity loss | Per month ≤3.0% | Fresh cell after 3month, 40%SOC, 25±2°C storage |
2.1.7 | Operating temperature(charging) | 0~60°C | Reference to paragraph 2.2 |
2.1.8 | Operatingtemperature (discharge) | -20~60°C | Reference to paragraph 2.3 |
2.1.9 | Cell Weight | 5.34±0.30Kg | N.A. |
2.1.10 | Storage Temp. | -30~60°C | Storage ambient humidity < 85% ROH, nocondensation |
2.1.11 | Typical dimension(W*H*T) | (Width):173.9±0. 8mm (Height):207.2±0. 8mm (Thickness):71.7±0.8 mm | Thickness with compression force (300±20Kgf), Height with Terminal, BOL(Reference to item 8) |
2.1.12 | Rest SOC | ≥5% | SOC interval without load or charging |
2.1.13 | Altitude | ≤2000m | N.A. |
2.1.14 | Cycle performance | ≥6000Cycles | cycle test b y the standardcharge and discharge method under300±20Kgf preload |
2.1.15 | Cycle fading | ≤5% | cycle test b y the standardcharge and discharge method under300±20Kgf preload for 180 cycles |
2.1.16 | Storage fading | ≤5% | 25±2°C , standard charging to 100% SOCstorage under 300±20Kgf preload for sixmonth |
2.Charging/Parameter for CATL 280Ah cell
No. | Parameter | Specification | Condition |
2.2.1 | Standard charge Power | 0.25P | 25±2 oC |
2.2.2 | Standard charge voltage | Cell max voltage 3.65V | N.A. |
2.2.3 | Standard charge method | 0.25P constant power charge to 3.65 V, rest 5min, 0.1P constant powercharge to 3.65V | |
2.2.4 | Standard chargetemperature | 25±2 °C | Cell Temperature |
2.2.5 | Absolute chargingtemperature(Cell Temperature) | 0~60°C | No matter what charge mode the battery is in,stop charging once the cell temperature exceeds absolute charge temperature range. |
2.2.6 | Absolute charging voltage | Max 3.65V | No matter what charge mode the battery is in,stop charging once the cell voltage exceeds absolute charge voltage. |
3.C-Rate Other charge Condition (C-Rate) for CATL 280Ah
Cell Temperature/°C | 0 | 5 | 10 | 15 | 20 | 25 | 45 | 50 | 55 | 60 | |
Max charge power(P) | 0%~<100%SOC | 0 | 0.05 | 0.10 | 0.20 | 0.35 | 0.5 | 0.5 | 0.5 | 0.5 | 0 |
4.Discharging/Parameter for CATL 280Ah LFP
No. | Parameter | Specification | Condition |
2.3.1 | Standard discharge power | 0.25P | 25±2 oC |
2.3.2 | Maximum discharge power (continuous) | 0.5P | N.A. |
2.3.3 | Discharge cut-off voltage | 2.5V2.0V | (Temp.)T>0°C (Temp.)T≤0°C |
2.3.4 | Standard discharge temperature | 25±2 °C | Cell temperature |
2.3.5 | Absolute discharge temperature | -20~60°C | Stop discharging once cell temperature is outside this range regardless of whether continuous or pulse current is adopted. |
5.C-Rate Other discharge Condition (C-Rate) for CATL 280Ah
Cell Temperature/°C | 0 | 5 | 10 | 15 | 20 | 25 | 45 | 50 | 55 | 60 | |
Max discharge power(P) | 0%~<100%SOC | 0.1 | 0.1 | 0.2 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0 |
6.High and Low temperature capacity FOR CATL 280Ah cell
No. | Parameter | Specification | Condition |
2.4.1 | Capacity@55°C | ≥280Ah | Fresh cell,55°C ,0.25P,2.5V~3.65V |
2.4.2 | Capacity@-20°C | ≥155Ah | Fresh cell,-20°C ,0.25P,2.0V~3.65V |
7.Cell temperature rise for CATL 280Ah battery cell
The temperature rise refers to the surface temperature of the cell after discharge minus the surface temperature of the cell before discharge. The measurement of the temperature rise of the cell should be carried out in a room where the ambient temperature is relatively stable and the space is large enough. For each cell temperature measurement, a calibrated temperature sensor that records time data should be selected.
No. | Parameter | Specification | Condition |
2.5.1 | Continuous dischargetemperature rise | ≤10°C | The cell is discharged in the standard discharge method. |
2.5.2 | Pulse dischargetemperature rise | ≤5°C | The cell is discharged at 500A for 10 s under any state ofcharge. |
8.CATL battery cell datasheet
Product Specification of CATL 202Ah Cell
CATL Battery 320AH Cell Datasheet
CATL 161Ah Cell Specification PDF
lifepo4 catl 228ah 3.2 v Specification
9.Custom battery cooling plate for 280Ah cell
custom multi-port tube cooling plate
We custom-manufacture multi-port tube cooling plates, also known as MPT coolers, battery flat tube coolers, or mini-channel tube cooling plates. These plates are brazed inside continuous brazing furnace,with high volume capacity and quality assurance. Multi-ports cooler are suitable for battery cooling applications using refrigerants such as 50% ethylene glycol, R1234yf, and Ra134.